Spécification(s):
  • CAT III 600V / CAT IV 300 V
  • indication automatique de polarité
  • réglage automatique du zéro
  • mesures de tension: 600 VCA et 600 VCC max.
  • mesures de courant: CC 15 A et CA 15 A max.
  • mesures de résistance: 200 MOhm max.
  • mesures de capacité: 200 µF max.
  • plage de mesure du thermocouple type K: de -50 °C à 800 °C
  • mesures de fréquence: 20 kHz
  • avec câbles de mesure séparés (incl.): [product name=TLM72]TLM72[/product]
  • degrée de pollution 2
  • [link url=http://www.velleman.eu/downloads/1/multimetres_categories_de_surtension_d_installation.pdf]Information importante concernant la sécurité[/link]
Caractéristique(s):
  • Caractéristiques physiques
  • Longueur du câble: 0.75 m
  • Hauteur (afficheur): 36 mm
  • Largeur (afficheur): 62 mm
  • Rétro éclairage: Oui
  • Affichage du nombre maximum de chiffres: 1999
  • Type d'affichage: LCD
  • Données électriques
  • Mesures du courant alternatif: 15 A, 2 mA, 20 mA, 200 μA, 200 mA
  • AC current:
    • basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
    • overload protection: 500 mA / 600 V, 15 A / 600 V fuse
    • frequency range: 40-500 Hz
  • Mesures de la tension alternative: 0-2 V, 20 V, 200 V, 600 V
  • AC voltage:
    • basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
    • input impedance: 1 megohm for 2 V range, 10 megohm for other ranges
    • frequency range: 40-500 Hz
    • maximum input: 600V DC or AC rms
    • test A: <= or <=
    • test B: >= or >=
  • Mesure de continuité audible: Oui
  • Audible continuity:
    • built-in buzzer sounds if resistance is less than 50 Ohm
    • test voltage: approx. 3 V
  • Indication automatique de la polarité: Oui
  • Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
  • Capacity:
    • basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
    • overload protection: 500 mA / 600 V fuse
  • Mesures du courant continu: 15 A, 2 mA, 20 mA, 200 μA, 200 mA
  • DC current:
    • basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
    • overload protection: 500 mA / 600 V, 15 A / 600 V fuse
  • Mesures de la tension CC: 0-200 mV, 2 V, 20 V, 200 V, 600 V
  • DC voltage:
    • basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
    • input impedance: 10 MOhm
    • maximum input: 600 V
    • overload protection: 600 V DC or AC rms
  • Test des diodes: Oui
  • Diode test specifications:

    test voltage: approx. 3 V (reversed DC voltage)

  • Frequency measurements: 20 kHz
  • Frequency:
    • basic accuracy: ± (2.0% rdg + 5 digits)
    • overload protection: 600 VDC or AC rms
    • sensitivity: sine wave 0.5 V rms
  • Type de fusible: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
  • Out of range indication: Yes
  • Temperature measuring Celsius specifications:
    • -50-150°C / 150-800°C
    • basic accuracy: ± (3°C + 3 digits) for -50-150°C range, ± (3% + 3 digits) for 150-800°C range
    • overload protection: 500 mA / 600V fuse
    • NiCr-NiSi sensor
    • K thermocouple probe: included
  • Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm
  • Resistance:
    • basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
    • overload protection: 600 VDC or AC rms
  • Transistor test: No
  • Données techniques
  • Degré de pollution: 2
  • Fonction data hold: Non
  • Catégorie de sécurité: CAT III 600 V, CAT IV / 300 V
  • Type de testeur de tension: CA/CC
  • Fonction d’extinction automatique: Oui
  • Données environnementales
  • Indice IP: IPX0
  • Pour usage dans: Intérieur uniquement
  • Taux d'humidité maximale de stockage: < 90 %
  • Humidité de fonctionnement maximale: < 80 %
  • Temps de fonctionnement (°C): 0-40 °C
  • Temps de fonctionnement (°F): 32-104 °F
  • Température de stockage (°C): -20-60 °C
  • Température de stockage (°F): -4-140 °F
  • Caractéristiques de fonctionnement
  • Langues (manuel d'instructions): Néerlandais, Anglais, Français, Allemand, Polonais, Portugais, Espagnol
  • Plage de mesure de la température (°C): -50-800 °C
  • Réglage de la gamme: Manuel
  • Alimentation
  • Nombre de piles: 1
  • Piles incluses: Oui
  • Pile IEC: E (6LR61, 6LP3146, 6F22, 6KR61, 6HR61 ,1604A, 1604D, 1604LC, 7.2H5, 11604, 11604M, PP3, 9 Volt, 006P, MN1604)
  • Composition de la pile: Alcaline
  • Indicateur de pile faible: Oui
  • Included
  • Set contents: test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
  • Informations de base sur le produit
  • Couleur: Noir
  • Couleur supplémentaire: Rouge
  • Profondeur: 40 mm
  • Hauteur: 190 mm
  • Poids: 300 g
  • Largeur: 100 mm
  • Matériau: ABS


  • EAN: 5410329642648