Spezifikation(en):
  • CAT III 600 V / CAT IV 300 V
  • automatische Anzeige der Polarität
  • automatische Nullstellung
  • Spannungsmessungen: 600 VAC und 600 VDC max.
  • Strommessungen: DC 15 A und AC 15 A max.
  • Widerstandsmessungen: 200 MΩ max.
  • Kapazitätsmessungen: 200 µF max.
  • Messbereich des K-Typ-Fühlers: -50 °C bis 800 °C
  • Frequenzmessungen: 20 kHz
  • mit separaten Messleitungen (mitgeliefert): [product name=TLM72]TLM72[/product]
  • Verschmutzungsgrad 2
  • [link url=http://www.velleman.eu/downloads/1/multimeter_overvoltage_installation_categories.pdf]Wichtige Sicherheitshinweise[/link]
Charakteristisch:
  • Physikalische Eigenschaften
  • Kabellänge: 0.75 m
  • Display-Höhe: 36 mm
  • Display-Breite: 62 mm
  • Hintergrundbeleuchtung: Ja
  • Anzeige der maximalen Ziffern: 1999
  • Display-Typ: LCD
  • Elektrische Daten
  • AC-Strommessungen: 15 A, 2 mA, 20 mA, 200 μA, 200 mA
  • AC current:
    • basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
    • overload protection: 500 mA / 600 V, 15 A / 600 V fuse
    • frequency range: 40-500 Hz
  • AC-Spannungsmessungen: 0-2 V, 20 V, 200 V, 600 V
  • AC voltage:
    • basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
    • input impedance: 1 megohm for 2 V range, 10 megohm for other ranges
    • frequency range: 40-500 Hz
    • maximum input: 600V DC or AC rms
    • test A: <= or <=
    • test B: >= or >=
  • Akustische Kontinuitätsmessung: Ja
  • Audible continuity:
    • built-in buzzer sounds if resistance is less than 50 Ohm
    • test voltage: approx. 3 V
  • Automatische Polaritätsanzeige: Ja
  • Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
  • Capacity:
    • basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
    • overload protection: 500 mA / 600 V fuse
  • DC-Strommessungen: 15 A, 2 mA, 20 mA, 200 μA, 200 mA
  • DC current:
    • basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
    • overload protection: 500 mA / 600 V, 15 A / 600 V fuse
  • DC-Spannungsmessungen: 0-200 mV, 2 V, 20 V, 200 V, 600 V
  • DC voltage:
    • basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
    • input impedance: 10 MOhm
    • maximum input: 600 V
    • overload protection: 600 V DC or AC rms
  • Diodentest: Ja
  • Diode test specifications:

    test voltage: approx. 3 V (reversed DC voltage)

  • Frequency measurements: 20 kHz
  • Frequency:
    • basic accuracy: ± (2.0% rdg + 5 digits)
    • overload protection: 600 VDC or AC rms
    • sensitivity: sine wave 0.5 V rms
  • Sicherung: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
  • Out of range indication: Yes
  • Temperature measuring Celsius specifications:
    • -50-150°C / 150-800°C
    • basic accuracy: ± (3°C + 3 digits) for -50-150°C range, ± (3% + 3 digits) for 150-800°C range
    • overload protection: 500 mA / 600V fuse
    • NiCr-NiSi sensor
    • K thermocouple probe: included
  • Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm
  • Resistance:
    • basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
    • overload protection: 600 VDC or AC rms
  • Transistor test: No
  • Technische Daten
  • Verschmutzungsgrad (Pollution degree): 2
  • Data-Hold-Funktion: Nein
  • Messkategorie: CAT III / 600 V, CAT IV / 300 V
  • Spannungstester-Typ: AC / DC
  • Automatische Abschaltung: Ja
  • Umgebungsdaten
  • Schutzart: IPX0
  • Einsatzbereich: Nur innen
  • Maximale Luftfeuchtigkeit bei Lagerung: < 90 %
  • Relative Luftfeuchtigkeit (max.): < 80 %
  • Betriebstemperatur (°C): 0-40 °C
  • Betriebstemperatur (°F): 32-104 °F
  • Lagertemperatur (°C): -20-60 °C
  • Lagertemperatur (°F): -4-140 °F
  • Gebrauchseigenschaften
  • Bedienungsanleitung verfügbar in folgenden Sprachen: Niederländisch, Englisch, Französisch, Deutsch, Polnisch, Portugiesisch, Spanisch
  • Temperatur-Messbereich (°C): -50-800 °C
  • Bereichseinstellung: Handbuch
  • Betriebsspannung
  • Anzahl Batterien: 1
  • Batterien: Ja
  • Batterie IEC-Größe: E (6LR61, 6LP3146, 6F22, 6KR61, 6HR61 ,1604A, 1604D, 1604LC, 7.2H5, 11604, 11604M, PP3, 9-volt, 006P, MN1604)
  • Batterietyp: Alkali-Mangan
  • Batteriewechselanzeige: Ja
  • Included
  • Set contents: test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
  • Produktinformationen
  • Farbe: Schwarz
  • Weitere Farbe: Rot
  • Tiefe: 40 mm
  • Höhe: 190 mm
  • Gewicht: 300 g
  • Breite: 100 mm
  • Material: ABS


  • EAN: 5410329642648
Product added to wishlist