MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A -  PLAGE AUTOMATIQUE - 4000 POINTS
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A -  PLAGE AUTOMATIQUE - 4000 POINTS
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A -  PLAGE AUTOMATIQUE - 4000 POINTS
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A -  PLAGE AUTOMATIQUE - 4000 POINTS
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III...
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III...
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III...
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III...

MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A - PLAGE AUTOMATIQUE - 4000 POINTS

DVM855
Disponible
29,96 €
TTC
MULTIMÈTRE NUMÉRIQUE - CAT. II 500 V / CAT. III 300 V - 10 A - PLAGE AUTOMATIQUE - 4000 POINTS

 
Spécification(s):
  • CAT II 500 V / CAT III 300 V
  • sélection de plage automatique et manuelle
  • indication automatique de polarité
  • réglage automatique du zéro
  • mesures de tension: 500 VCA et 500 VCC max.
  • mesures de courant: DC 10 A et CA 10 A max.
  • mesures de résistance: 40 MΩ max.
  • mesures de capacité: 100 µF max.
  • mesures de fréquence: 5.12 MHz max.
  • avec câbles de mesure séparés TLM73 (incl.): [product name=TLM73]TLM73[/product]
  • degrée de pollution 2
  • [link url=http://www.velleman.eu/downloads/1/multimetres_categories_de_surtension_d_installation.pdf]Information importante concernant la sécurité[/link]
Caractéristique(s):
  • Caractéristiques physiques
  • Longueur du câble: 0.7 m
  • Hauteur (afficheur): 21 mm
  • Largeur (afficheur): 47 mm
  • Rétro éclairage: Oui
  • Affichage du nombre maximum de chiffres: 4000
  • Type d'affichage: LCD
  • Données électriques
  • Mesures du courant alternatif: 0-400 μA, 10 A, 4 A, 4 mA, 40 mA, 400 mA
  • AC current:
    • basic accuracy: ± (1.5% rdg + 3 digits), ± (2.5% rdg + 5 digits) for 4 A to 10 A range
    • overload protection: 0.5 A / 500 V fuse for µA and mA range; 10 A / 500 V for 10 A range
  • Mesures de la tension alternative: 0-4 V, 40 V, 400 V, 500 V
  • AC voltage:
    • basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 500 V range
    • input impedance: 10 MOhm
    • frequency range: 40-500 Hz
    • maximum input: 500V DC or AC rms
  • Mesure de continuité audible: Oui
  • Audible continuity:

    built-in buzzer sounds if resistance is less than 50 Ohm

  • Indication automatique de la polarité: Oui
  • Battery test measurements: 1.5 V, 9 V
  • Battery test:
    • basic accuracy: ± (5.0% rdg + 5 digits)
    • overload protection: 0.5 A / 500 V fuse
  • Capacity measurements: 0-51.2 nF, 100 µF, 51.2 µF, 512 nF
  • Capacity:
    • basic accuracy: ± (3.0% rdg + 10 digits), ± (2.5% rdg + 5 digits) for 512 nF to 51.2 µF range; ± (5.0% rdg + 10 digits) for 100 µF range
    • overload protection: 500V DC or AC rms
  • Mesures du courant continu: 10 A, 4 A, 4 mA, 40 mA, 400 mA
  • DC current:
    • basic accuracy: ± (1.2% rdg + 2 digits), ± (2.0% rdg + 3 digits) for 4 A to 10 A range
    • overload protection: 0.5 A / 500 V fuse for µA and mA range; 10 A / 500 V for 10 A range
  • Mesures de la tension CC: 0-400 mV, 4 V, 40 V, 400 V, 500 V
  • DC voltage:
    • basic accuracy: ± (0.5% rdg + 2 digits) , ± (0.8% rdg + 2 digits) for 500 V range
    • input impedance: > 10 MOhm
    • overload protection: 500 V DC or AC rms
  • Test des diodes: Oui
  • Diode test specifications:
    • test forward voltage of diode
      • test voltage: approx. 1.5 V
  • Duty cycle:
    • 0.1% to 99.9%
      • basic accuracy: ± (2.0% rdg + 2 digits)
      • sensitivity: sine wave 0.6 V rms
      • overload protection : 500V DC or AC rms
  • Frequency measurements: 0-5.12 Hz, 5.12 kHz, 5.12 MHz, 51.2 Hz, 51.2 kHz, 512 Hz, 512 kHz
  • Frequency:
    • basic accuracy: ± (0.1% rdg + 5 digits)
    • sensitivity: sine wave 0.6 V rms (10 MHz = 1.5 V rms)
    • overload protection: 500V DC or AC rms
  • Type de fusible: F 0.50 A / 500 V, 5 x 20 mm, F 10 A / 1000 VAC / 1000 VDC, 5 x 20 mm
  • Out of range indication: Yes
  • Resistance measurements: 0-400 Ohm, 4 kOhm, 4 MOhm, 40 kOhm, 40 MOhm, 400 kOhm
  • Resistance:
    • basic accuracy: ± ( 1.0% rdg +3 digits); ± (1.0% rdg + 2 digits) for 4 kOhm to 4MOhm range, ± (1.5% rdg + 3 digits) for 40 MOhm range
    • overload protection: 500 V DC or AC rms
  • Transistor test: No
  • Duty cycle measurements: 0.1-99.9 %
  • Données techniques
  • Degré de pollution: 2
  • Fonction data hold: Oui
  • Catégorie de sécurité: CAT III 300 V
  • Type de testeur de tension: CA/CC
  • Fonction d’extinction automatique: Oui
  • Données environnementales
  • Indice IP: IPX0
  • Pour usage dans: Intérieur uniquement
  • Taux d'humidité maximale de stockage: < 90 %
  • Humidité de fonctionnement maximale: < 80 %
  • Temps de fonctionnement (°C): 0-40 °C
  • Temps de fonctionnement (°F): 32-104 °F
  • Température de stockage (°C): -20-60 °C
  • Température de stockage (°F): -4-140 °F
  • Caractéristiques de fonctionnement
  • Langues (manuel d'instructions): Néerlandais, Anglais, Français, Allemand, Polonais, Portugais, Espagnol
  • Réglage de la gamme: Automatique, Manuel
  • Alimentation
  • Nombre de piles: 2
  • Piles incluses: Oui
  • Pile IEC: AAA (LR03, R03, FR03, HR03, KR03, ZR03, 24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400)
  • Composition de la pile: Alcaline
  • Indicateur de pile faible: Oui
  • Included
  • Set contents:

    test lead probe : CAT III 600 V - 12 A - 18 AWG - 70 cm

  • Informations de base sur le produit
  • Couleur: Gris
  • Couleur supplémentaire: Rouge
  • Profondeur: 30 mm
  • Hauteur: 138 mm
  • Poids: 120 g
  • Largeur: 74 mm
  • Matériau: ABS


  • EAN: 5410329669713
Product added to wishlist
Product added to compare.

« En poursuivant votre navigation, vous déclarez avoir pris connaissance de notre politique de confidentialité et vous acceptez le dépôt de cookies tiers destinés à vous proposer des vidéos, des boutons de partage, des flux de contenus de plateformes sociales ».